| Logan |
OPEN |
Conduit_Length |
No |
879390 |
GTO |
56
|
2026-05-04 |
Trim conduit to 3-6 inches |
| Logan |
OPEN |
Conduit_Length |
No |
879390 |
GTO |
56
|
2026-05-04 |
Trim conduit to 3-6 inches |
| Logan |
OPEN |
Conduit_Length |
No |
879390 |
GTO |
49
|
2026-05-11 |
trim conduit to 3-6 inches |
| Logan |
OPEN |
Structure_Tracer_Wire |
No |
879390 |
GTO |
47
|
2026-05-13 |
Strip tracer wire and attach it to the ground wire with a wire nut. |
| Logan |
OPEN |
Conduit_Entry |
No |
879390 |
GTO |
47
|
2026-05-13 |
Expose stubbout to vault |
| Logan |
OPEN |
Structure_Gravel |
No |
873612 |
Alpha One |
26
|
2026-06-03 |
remove vault and place a 6 inches barrier of gravel for the vault. Replace it and add gravel inside the vault. |
| Logan |
OPEN |
Structure_Tracer_Wire |
No |
873612 |
Alpha One |
21
|
2026-06-08 |
Strip 7 way and attach it to the ground wire with a wire number. ( You can use a regular tracer and attach it as an extension of the 7 way. |
| Logan |
OPEN |
Locate_Isolation_Switch |
No |
879390 |
GTO |
20
|
2026-06-09 |
install isolation switch. Strip tracer wires and attach them to the isolation switch. Attach the Ground wire to the isolation switch. |
| Logan |
OPEN |
Conduit_Entry |
No |
873612 |
Alpha One |
14
|
2026-06-15 |
expose stubbout to vault. |
| Logan |
OPEN |
Restoration_Trench |
No |
879390 |
GTO |
14
|
2026-06-15 |
Fill trench hole with flow fill. |
| Logan |
OPEN |
Restoration_Trench |
No |
879390 |
GTO |
14
|
2026-06-15 |
Fill hole in trench with flowfill. |
| Logan |
OPEN |
Restoration_Trench |
No |
879390 |
GTO |
14
|
2026-06-15 |
Fill hole in trench with flow fill. |
| Logan |
OPEN |
Restoration_Trench |
No |
879390 |
GTO |
14
|
2026-06-15 |
Fill hole in trench with flow fill. |
| Logan |
OPEN |
Structure_Tracer_Wire |
No |
873612 |
Alpha One |
12
|
2026-06-17 |
strip tracers and attach them to the ground wire with a wire nut. |
| Logan |
OPEN |
Structure_Grounding |
No |
873612 |
Alpha One |
12
|
2026-06-17 |
Install Ground wire. Strip tracer wires and attach them to the ground wire with a wire nut. |
| Logan |
OPEN |
Restoration_Trench |
No |
879390 |
GTO |
12
|
2026-06-17 |
Fill hole with flowfill |
| Logan |
OPEN |
Structure_Gravel |
No |
869060 |
Hughes 3 |
0
|
2026-06-29 |
Lift vault and place a 4 inch base of gravel. |
| Logan |
OPEN |
Structure_Tracer_Wire |
No |
869060 |
Hughes 3 |
0
|
2026-06-29 |
Strip tracer wires and attach them with a wire nut. |
| Logan |
OPEN |
Structure_Gravel |
No |
ECC |
Ervin |
0
|
2026-06-29 |
Lift vault and place a 4 inch base of gravel. |
| Logan |
OPEN |
Restoration_Trench |
No |
879390 |
GTO |
0
|
2026-06-29 |
Fill trench with flow fill. |
| Logan |
OPEN |
Restoration_Trench |
No |
879390 |
GTO |
0
|
2026-06-29 |
Fill trench with flow fill. |